calculating rectangular hopper discharge rate

  • To my Mom and Dad

    The present work investigates hopper discharge phenomenon from a quasi-3D, rectangular hopper using the Discrete Element Method. Accurate prediction of the discharge rate from hoppers is important in many industrial processes involving the handling of granular materials.

  • Rectangular Weir Discharge Calculator and Equations

    Rectangular Weir Equation. The Kindsvater-Carter rectangular weir equation (ISO, 1980): The sum b+K b is called "effective width" and the sum h+K h is called "effective head." The value for g is 9.8066 m/s 2 and K h =0.001 m. C e is a function of b/B and h/P, and K b is a function of b/B.

  • An Overview of Hopper and Design Procedure of a Pyramid ...

    Calculate discharge rate (mass flow rate),: There are number of methods for calculating discharge rates from silos or hoppers. For coarse particles such as rice which have diameter less than 500 microns there are two equations commonly used one for mass flow and one for funnel flow. c) For mass flow hopper,

  • Fine Powder Flow Phenomena in Bins, Hoppers, and ...

    flow bin having a square or rectangular outlet will tend to develop a circular flow channel (and resulting rathole) whose diameter is approximately equal to the length of the diagonal of the outlet. When a rathole develops in a funnel flow bin, e.g. as the bin level drops when the in-feed rate is slower than the discharge rate, a condition is

  • Episode 38 : Bin and Hopper Design

     · Discharge Rate - Example An engineer wants to know how fast a compartment on a railcar will fill with polyethylene pellets if the hopper is designed with a 6" Sch. 10 outlet. The car has 4 compartments and can carry 180000 lbs.

  • INSTALLATION AND SYSTEM GUIDELINES

    and the discharge commences. The rate at which the dis-charge takes place is controlled by monitoring the "loss in weight" of the hopper and then modulating the discharge rates to maintain the desired flow rate. The discharge may be ended at the completion of the process step, or when a specific amount of material has been discharged.

  • Effect of Particle Shape on Hopper Discharge Rate

    A B Figure 2-1. Schematic of the rectangular hoppers used for discharge rate measurements. A) Flat -bottomed hopper. B) Angl ed hopper making 55 with the vertical. 41 PAGE 42 42 Figure 2-2. Cross-section of the rectangular hoppers used for discharge rate measurements. PAGE 43 Figure 2-3.

  • Biosolids Technology Fact Sheet Gravity Thickening

    To assist solids transport, gravity thickener bottoms are constructed with a floor slope between 1:6 and 1:3. Rectangular units have been used as gravity thickeners. For example, obsolete rectangular clarifiers have been converted for use as gravity thickeners. However, rectangular units generally prove to be unsatisfactory.

  • Volumetric Flow Rate & Rectangular Duct Width x Height to ...

    This tool will calculate the velocity in any units from the specified volumetric flow rate of a substance flowing through a rectangular duct of a defined width and height. For each new calculation a unique conversion scale will be generated for the range of volumetric flow rates and flow speeds for the length and width specified.

  • Rectangular Open Channel Flow and Hydraulic Design

    In our rectangular open channel flow calculation, most of the combinations of inputs have analytic (closed form) solutions to compute the unknown variables; however, two require numerical solutions ("Enter Q, n, S, y" and "Enter Q, n, S, b"). Our numerical solutions utilize a cubic solver. All of our calculations utilize double precision.

  • Investigation into flow rate characteristics ofbulk ...

    D. To find out relationship between discharge flow rate of different bulk solids and width of gate opening, the height of material inside the hopper remaining constant. E. To investigate the effect of angle of slope of the conical portion of the hopper on the discharge flow rate of different bulk materials. III.Experimental Set Up Gap

  • Calculating Rectangular Hopper Discharge Rate

     · How to calculate the discharge rate from a rectangular hopper? Beverloo formulation is widely used for predicting the discharge rate from a flat-bottomed cylindrical silo with a circular opening. Myers and Sellers(1971) extended the correlation to a flat-bottomed(90 ) rectangular hopper outlet of width Wo and length L, and predicted the discharge rate as 31247 Typically, the flowing …

  • Hopper Design Principles

     · The length of the screw must be between three and six times the width of the hopper to meet fabrication tolerances, and the screw diameter is equal to the hopper width. Discharge rate. For coarse powders, the maximum discharge rate from a mass flow hopper …

  • Tank Emptying Time Calculator

    Tank Emptying Time Calculator. The tank discharge flow rate through its exit orifice is calculated as follows: Flow rate =. orifice discharge coefficient x. orifice cross-sectional area x. square root (2gH) where g = acceleration due to gravity. where H = head of fluid above the outlet. As the tank empties, the remaining fluid head inside the ...

  • Silo Discharge Rate Calculation

     · Discharge Rate fron Silos. Mahmoud, I will be glad to send the equations that you can use to calculate the discharge rates from silos for granular solids. Please send me an email with full information about yourself and your Company. Regards, Amrit Agarwal. Consulting Engineer. Pneumatic Conveying Consulting. Email [email protected] .

  • Determining Discharge Rates of Particulate Solids | AIChE

    Determining Discharge Rates of Particulate Solids. May. 2016. Shrikant Dhodapkar, Karl V. Jacob, Madhusudhan Kodam. Many factors affect the flowrate of bulk solids. This article reviews the underlying physics of solids flow and explains how to calculate the discharge rate of solids from processing and handling equipment.

  • V notch Weir Calculator − Online Calculation of water flow ...

    This V Notch calculator computes the flow rate of a triangular weir using the values of its hydraulic head and notch angle. This calculator is used to calculate the discharge of a fully contracted weir flow. What is a V-notch weir? Flow rates of streams and canals are determined usually by installing a weir.

  • Screw Feeder Design for Metering Bulk Materials ...

     · A hopper is typically square or rectangular in shape with sloped bottom and limited storage capacity. A bin is very similar to a hopper but with larger storage capacity. A silo is cylindrical in shape with cone or mass-flow bottom and large storage capacity. ... A screw feeder''s discharge rate can be accurately determined by speed control and ...

  • Hopper design made easy!

     · Hopper design is easy! If you want to prevent obstructions to flow, just make the hopper outlet large enough. Ditto if you want your powder to discharge at a desired rate. If …

  • How to Calculate the Volume of a Tapered Hopper | Hunker

    Calculate the volume by substituting in the values for the variables: V= (1/3) H [ (X^2_Y-x^2_y)/ (X-x)] where: H: Height between bases (shortest distance through middle of hopper) X: Length of upper rectangular base Y: Width of upper rectangular base x: Length of lower rectangular base y: Width of lower rectangular base. Advertisement.

  • Trapezoidal Open Channel Design Calculation

    However, if you wish to simulate a rectangular channel, you can set one of them to 0.0 and the other to a very small positive number such as 0.00001. Or, you can use our rectangular open channel calculation. Triangular channels can be modeled by setting the bottom width, b, to a very small positive number such as 0.001 m or as low as 10-9 m.

  • Hopper Volumes: Program to Calculate the Volume Surface ...

    Pyramid Hopper Volume Calculation 44 (0)1204 386723 [email protected] .uk Hopper Volumes: Program to Calculate the Volume, Surface Area and Weight of a Pyramid Shaped Hopper.

  • SUMMARY OF KEY WASTEWATER MATH FORMULAS

    Hydraulic Cross- Check Formulas 1. Detention = (Volume, gals) x ( 24 Hrs./day ) Time, Hrs. ( Total 24 Hr. Flow, gals/day ) Design Data: 1 - 2.5 Hours; Average 1.5 hours.

  • CalcTool: Gravity-fed pipe flow calculator

    This calc is mainly for pipes full with water at ambient temperature and under turbulent flow. If you know the slope rather than the pipe length and drop, then enter "1" in "Length" and enter the slope in "Drop". If the cunduit is not a full circular pipe, but you know the hydraulic radius, then enter (Rh×4) in "Diameter".

  • Effect of Types of Weir on Discharge

    discharge is important as the knowledge of the accurate measurement of discharges helps in understanding of the flow mechanism as well as designing the hydraulic structures for future. Structures such as rectangular weir, vee notch weir and crump weir are placed in a channel to measure the flow rate.

  • LAB REPORT

    conducted to investigate the characteristics of flow that showed by a rectangular and V-shaped Weir. The difference in flow rate of water that flows into both of the channel was observed. Besides that, the discharge coefficient of fluid flow was determined by calculation of this experiment values and compared with the accepted values.

  • Discharge characteristics of binary particles in a ...

     · The stable discharge of particles through the hopper plays a key role in many industrial applications. In order to investigate the discharge characteristics of binary particles in a rectangular hopper with an inclined bottom, the discrete element method (DEM) was used to simulate the discharge process. The accuracy of DEM was validated by comparing calculated and experimental values.

  • Granular Flow in Silo Discharge: Discrete Element Method ...

    granular rheology, and on the silo discharge rate. Note that Beverloo''s correlation of experimental data that is widely used to calculate the discharge rate18 does not include the effect of particle friction. Anand et al.27 studied the discharge from a 3D rectangular hopper using DEM …

  • Syntron Material Handling

    In addition, a properly designed hopper produces a depth of discharged material that is slightly lower than the height of the hopper gate varying based upon the particle size and cohesion of the material. Uniform flow is achieved with the ratio of the hopper throat (T) and the hopper gate height (H) is 0.6. This ratio is expressed as T/H.

  • Bulk Storage Hopper Flow & Feeder

     · Discharge from a small outlet, even in mass flow, develops a much higher flow rate than extraction over the larger area of an outlet slot, so increasing the tendency to carry air down with the product. The extra capacity afforded by a ''V'' shaped hopper also extends the residence time of the hopper contents.

  • Rainwater Systems

    5. Hopper Heads The flow capacities of different size hopper heads are shown in the table below and are based on a rainfall intensity of 0.021 l/s per square metre of roof area. Product Pipe Roofthe appropriate factor for the roof slope can Flow rate Code Size Area litres/ m2 second RH252 68mm 247m2 5.14l/s RH25 68mm 360m2 7.56l/s

  • Calculating Channel Froude Numbers for Flumes and Weirs

    Channel shape: Rectangular. Channel depth: 1-feet (at maximum flow) Channel width: 3-feet. Flow rate: 9-cubic feet/sec (which gives us a velocity of 3-cubic feet/sec as Q (flow rate) = A (area) * V (velocity), A = 3*1) From this the Froude number can be calculated as: With the Froude number verified, the rancher can proceed with the ...

  • COMPUTATION OF PEAK DISCHARGE AT CULVERTS

    The discharge coeffi­ cient applicable to each flow type is listed for the more common entrance geometries. Pro­ cedures for computing peak discharge through culverts are outlined in detail for each of the six flow types. INTRODUCTION The culvert is frequently used as an indirect means of determining peak discharge from small drainage areas.

  • Measuring flow in open channels (weirs)

    Discharge Rectangular and suppressed weirs have the same general discharge equation (below), but differing weir lengths that the water flows over √ 𝐷 =0.602+0.083 /𝑃 Where: Q (m³/s) is the volumetric flow rate over the weir 𝐷 is the discharge coefficient usually ranging from 0.60 to 0.62

  • Hopper and silo bulk discharge flow rate calculation

    Hopper and silo bulk discharge flow rate calculation

  • How to Design Horizontal Flow Settling Tanks? | Waste ...

    In the design of inlets to rectangular tanks the following methods are used to distribute the flow uniformly across the tank: (a) Multiple pipe inlets with baffle boards of depth 0.45 to 0.6 m in front of the inlets, 0.6 to 0.9 m away from it and with the top of baffle being 25 …

  • Predicting discharge dynamics from a rectangular hopper ...

     · Myers and Sellers (1971) extended the correlation to a flat-bottomed (90°) rectangular hopper outlet of width W o and length L, and predicted the discharge rate as (3) W ˙ flat bottom = 1.03 ρ flow g 1 / 2 (L-kd) (W o-kd) 3 / 2 Note that the discharge rate varies as (W o-kd) 3 / 2 in this case instead of (W o-kd) 5 / 2 as for the case of ...

  • Critical Settling Velocity & settling Velocity (Overflow rate)

    Design the plain rectangular sedimentation tank for a water purification of an hourly output 5000m 3, then get the amount if the sludge in the S.S if the raw wastewater has SS concentration 80ppm and the sludge specific gravity is 1.1?

  • CHAPTER 3 PRIMARY TREATMENT

    8 Figure 3.3 – Scum Collection for a Rectangular Clarifier 9 10 In Table 3.2 we see the basic design dimensions of both rectangular and circular primary 11 settling tanks. Note that for both designs, depth is typically the same. There are several key 12 elements to the primary settling process.